Heat Pump Running Cost

Divide heat demand by seasonal performance and apply your electricity price without regional price or climate assumptions.

This selection sets the currency unit only; amounts are not converted using exchange rates.
kWh/year
USD/kWh

Heat demand is not electricity use

Heat demand is the useful heat required during a year. The calculator divides it by the seasonal-performance input. A heat demand of 12,000 kWh with a seasonal factor of 4 produces an estimated 3,000 kWh of electricity use.

How to use the calculator

  1. Select the currency for your electricity-price input.
  2. Enter annual building heat demand.
  3. Prefer a seasonal performance factor or measured annual performance over a laboratory COP.
  4. Enter your electricity price per kWh and calculate consumption plus annual and monthly-average cost.

COP, SCOP, and annual performance

COP describes one test point. SCOP combines standardized operating conditions. A measured annual performance factor compares delivered heat with electricity used across a real year. The seasonal or measured figure is usually more useful for running-cost estimates.

Why actual cost can differ

Hot water, backup resistance heat, pumps, defrost cycles, outdoor temperature, flow temperature, occupancy, and tariff changes can alter consumption. Monthly cost is only annual cost divided by twelve, not a forecast for each month. Purchase cost and payback belong in the related investment calculator.

Frequently Asked Questions

How does heat demand become electricity use?
The calculator divides annual heat demand by the seasonal-performance input. 12,000 kWh of heat at a factor of 4 produces an estimated 3,000 kWh of electricity.
Should I use COP, SCOP, or annual performance?
For annual cost, a measured annual performance factor or suitable SCOP is usually more representative than COP at one test condition.
How does electricity price affect the result?
Estimated electricity use is multiplied directly by your price per kWh. The currency selector changes the unit only and performs no exchange-rate conversion.
Are hot water and backup resistance heat included?
Only when the heat demand or annual-performance figure you use already includes them. The calculator does not add separate auxiliary consumption automatically.
Why can actual cost be higher or lower?
Weather, flow temperature, defrosting, occupancy, maintenance condition, auxiliary electricity, and tariff changes affect actual performance.
How can I compare cost with my previous heating system?
Compare the same system boundaries and complete energy costs. You can then use the annual difference in the related investment-payback calculator.